-
1 local high-velocity currents
Англо-русский словарь промышленной и научной лексики > local high-velocity currents
-
2 паразитные токи
1) General subject: earth currents2) Engineering: foreign currents3) Railway term: local currents, sneak currents4) Telecommunications: parasitic currents, spurious currents, stray currents5) Electronics: parasite currents -
3 вихревые токи
1) Engineering: Foucault currents, whirling currents2) Railway term: vortical currents3) Telecommunications: eddy current4) Household appliances: vortex currents5) Makarov: eddy currents (токи Фуко), local currents6) Electrical engineering: eddy currents -
4 токи Фуко
1) Engineering: Foucault currents, eddy currents2) Railway term: local currents, vortical currents3) Oil: eddy current4) Geophysics: Foucault current5) Makarov: eddy currents (вихревые токи) -
5 распределительное устройство
- switchyard
- switching substation
- switchgear
- switchboard
- switch-gear
- gear
- energy distribution board
- distribution
распределительное устройство
Распределительным устройством (РУ) называется электроустановка, служащая для приема и распределения электроэнергии и содержащая сборные и соединительные шины, коммутационные аппараты, вспомогательные устройства (компрессорные, аккумуляторные и др.), а также устройства защиты, автоматики и измерительные приборы.
[РД 34.20.185-94]
распределительное устройство
Электроустановка, предназначенная для приема и распределения электрической энергии на одном напряжении и содержащая коммутационные аппараты и соединяющие их сборные шины [секции шин], устройства управления и защиты.
Примечание. К устройствам управления относятся аппараты и связывающие их элементы обеспечивающие контроль, измерение, сигнализацию и выполнение команд.
[ ГОСТ 24291-90]
[ ГОСТ Р 53685-2009]
электрическое распределительное устройство
распределительное устройство
Устройство, предназначенное для приема и распределения электроэнергии на одном напряжении и содержащее коммутационные аппараты и соединяющие их сборные соединительные устройства.
Примечание. В состав распределительного устройства дополнительно могут входить устройства защиты и управления
[ОСТ 45.55-99]
распределительное устройство
Электроустановка, служащая для приема и распределения электроэнергии и содержащая коммутационные аппараты, сборные и соединительные шины, вспомогательные устройства (компрессорные, аккумуляторные и др.), а также устройства защиты, автоматики и измерительные приборы.
[ПОТ Р М-016-2001]
[РД 153-34.0-03.150-00]
устройство распределительное
Совокупность аппаратов и приборов для приёма и распределения электроэнергии одного напряжения, вырабатываемой электростанцией или преобразуемой подстанцией
[Терминологический словарь по строительству на 12 языках (ВНИИИС Госстроя СССР)]EN
switching substation
a substation which includes switchgear and usually busbars, but no power transformers
[IEV number 605-01-02]FR
poste de sectionnement
poste de coupure
poste comprenant des organes de manoeuvre et généralement des jeux de barres, à l'exclusion de transformateurs de puissance
[IEV number 605-01-02]В качестве РУ 6—10 кВ используется сборка высокого напряжения с однополюсными разъединителями и вертикальным расположением фаз одного присоединения и одна камера КСО с выключателем нагрузки и предохранителями для подключения трансформатора. Для РУ 0,4 кВ применяются сборки низкого напряжения с предохранителями и вертикальным расположением фаз одного присоединения.
На ПС применяются открытые (ОРУ), закрытые (ЗРУ) или комплектные (КРУ) распределительные устройства.
[ http://energy-ua.com/elektricheskie-p/klassifikatsiya.html]
В общем случае ПС и РУ являются составной частью электроустановок, которые различаются:
-
по назначению:
- генерирующие,
- преобразовательно-распределительные,
-
потребительские.
Генерирующие электроустановки служат для выработки электроэнергии, преобразовательно-распределительные электроустановки преобразуют электроэнергию в удобный для передачи и потребления вид, передают ее и распределяют между потребителями;
-
по роду тока:
- постоянного тока,
- переменного тока.
-
по напряжению:
- до 1000 В,
- выше 1000 В.
ГОСТ 29322—92 установлена следующая шкала номинальных напряжений:
Шкала номинальных напряжений ограничена сравнительно небольшим числом стандартных значений, благодаря чему изготавливается небольшое число типоразмеров машин и оборудования, а электросети выполняются более экономичными. В установках трехфазного тока номинальным напряжением принято считать напряжение между фазами (междуфазовое напряжение). Согласнодля электросетей переменного тока частотой 50 Гц междуфазовое напряжение должно быть: 12, 24, 36, 42, 127, 220, 380 В; 3, 6, 10, 20, 35, 110, 150, 220, 330, 500, 750 и 1150 кВ;
для электросетей постоянного тока: 12, 24, 36, 48, 60, 110, 220, 440, 660, 825, 3000 В и выше.-
по способу присоединения к электросети ПС разделяются на:
- тупиковые (блочные),
- ответвительные (блочные),
- проходные (транзитные)
- узловые.
Тупиковые ПС получают питание по одной или двум тупиковым ВЛ.
Ответвительные ПС присоединяются ответвлением к одной или двум проходящим ВЛ с односторонним или двухсторонним питанием.
Проходные ПС включаются в рассечку одной или двух проходящих ВЛ с односторонним или двухсторонним питанием.
Узловые ПС кроме питающих имеют отходящие радиальные или транзитные ВЛ.-
по способу управления ПС могут быть:
- только с телесигнализацией,
- телеуправляемыми с телесигнализацией,
- с телесигнализацией и управлением с общеподстанционного пункта управления (ОПУ).
Подстанции оперативно обслуживаются постоянным дежурным персоналом на щите управления, дежурными на дому или оперативно-выездными бригадами (ОВБ). Ремонт ПС осуществляется специализированными выездными бригадами централизованного ремонта или местным персоналом подстанции.
В РУ напряжением до 1000 В провода, шины, аппараты, приборы и конструкции выбирают как по нормальным условиям работы (напряжению и току), так и по термическим и динамическим воздействиям токов коротких замыканий (КЗ) или предельно допустимой отключаемой мощности.
В РУ и ПС напряжением выше 1000 В расстояния между электрооборудованием, аппаратами, токоведущими частями, изоляторами, ограждениями и конструкциями устанавливаются так, чтобы при нормальном режиме работы электроустановки возникающие физические явления (температура нагрева, электрическая дуга, выброс газов, искрение и др.) не могли привести к повреждению оборудования и КЗ.[ http://energy-ua.com/elektricheskie-p/klassifikatsiya.html]
Several different classifications of switchgear can be made:- By the current rating.
-
By interrupting rating (maximum short circuit current that the device can safely interrupt)
- Circuit breakers can open and close on fault currents
- Load-break/Load-make switches can switch normal system load currents
- Isolators may only be operated while the circuit is dead, or the load current is very small.
-
By voltage class:
- Low voltage (less than 1,000 volts AC)
- Medium voltage (1,000–35,000 volts AC)
- High voltage (more than 35,000 volts AC)
-
By insulating medium:
-
By construction type:
- Indoor (further classified by IP (Ingress Protection) class or NEMA enclosure type)
- Outdoor
- Industrial
- Utility
- Marine
- Draw-out elements (removable without many tools)
- Fixed elements (bolted fasteners)
- Live-front
- Dead-front
- Open
- Metal-enclosed
- Metal-clad
- Metal enclosed & Metal clad
- Arc-resistant
-
By IEC degree of internal separation
- No Separation (Form 1)
- Busbars separated from functional units (Form 2a, 2b, 3a, 3b, 4a, 4b)
- Terminals for external conductors separated from busbars (Form 2b, 3b, 4a, 4b)
- Terminals for external conductors separated from functional units but not from each other (Form 3a, 3b)
- Functional units separated from each other (Form 3a, 3b, 4a, 4b)
- Terminals for external conductors separated from each other (Form 4a, 4b)
- Terminals for external conductors separate from their associated functional unit (Form 4b)
-
By interrupting device:
-
By operating method:
- Manually operated
- Motor/stored energy operated
- Solenoid operated
-
By type of current:
-
By application:
-
By purpose
- Isolating switches (disconnectors)
- Load-break switches.
- Grounding (earthing) switches
A single line-up may incorporate several different types of devices, for example, air-insulated bus, vacuum circuit breakers, and manually operated switches may all exist in the same row of cubicles.
Ratings, design, specifications and details of switchgear are set by a multitude of standards. In North America mostly IEEE and ANSI standards are used, much of the rest of the world uses IEC standards, sometimes with local national derivatives or variations.
[Robert W. Smeaton (ed) Switchgear and Control Handbook 3rd Ed., Mc Graw Hill, new York 1997]
[ http://en.wikipedia.org/wiki/High_voltage_switchgear]Тематики
- электрификация, электроснабж. железных дорог
- электроагрегаты генераторные
- электробезопасность
- электроснабжение в целом
Синонимы
EN
- distribution
- energy distribution board
- gear
- switch-gear
- switchboard
- switchgear
- switching substation
- switchyard
DE
FR
Русско-английский словарь нормативно-технической терминологии > распределительное устройство
-
6 вихревые токи
eddy currents, local current -
7 вихревые токи
eddy currents, local currentРусско-английский словарь по радиоэлектронике > вихревые токи
-
8 определять
Определять - to determine, to estimate, to assess (расчётом, измерением); to infer (логически); to diagnose (диагностировать); to detect (обнаруживать); to identify (опознавать, выявлять); to control, to govern, to dictate, to dominate, to establish (обуславливать, играть главную роль); to define (формулировать), to measure (знания, способности)No capital cost penalty was assessed against this design. (Увеличение капитальных затрат для этой конструкции не определялось.)A second critical number at 2200 was inferred, based on further changes in the shape of the local mass transfer rate profile, to indicate the onset of vortex shedding in the separated region.Inasmuch as those measured values of the position cause greatly magnified errors in the second divided difference, it was possible to detect which measurements were not precisely correct.By this process, an axial station was identified at which the pure downstream motion was punctuated by the lunges of the reattachment zone.A similar result was reported in [...] for cantilever designs with short spans, where bearing deflection controls pinion motion. An opposite trend is displayed for the straddle where the shaft, stiffened by a decrease in length, dictates pinion deflection.However, manufacturing considerations will establish a minimum practical fin thickness.Finally, the convection currents become established and dominate the heat transfer.Also calculated were the transferred volume and the void volume, both of which will be defined in the section describing the transfer model.The testing measures your command of the English language in the areas of listening, reading, writing, and speaking.Определять(ся) поAs the fan blade material is titanium the pressure instrumented blades are identified magnetically by a flame sprayed soft iron patch applied to the blade tips.The temperature gradient on the surface can be determined from the temperature profile.System stability was indicated by a vanishing of the sustained oscillatory behavior and the reappearance of the inherent random fluctuations.Defect size can thus be measured by frequency as follows.F(Tw/T) was found to be unity in this regime if all properties were based on the film temperature.Русско-английский научно-технический словарь переводчика > определять
См. также в других словарях:
Local field potential — A local field potential (LFP) is a particular class of electrophysiological signals, which is related to the sum of all dendritic synaptic activity within a volume of tissue. BackgroundA signal is recorded using a low impedance extracellular… … Wikipedia
Currents (TV series) — Currents Presented by Matt McClure and Francesca Maxime Country of origin United States Language(s) English No. of episodes 130 (as of January 13, 2010) … Wikipedia
local action — noun 1. : voltaic action at an electrode of an electrolytic cell consisting of currents set up in the electrolyte between chemically different areas due to impurities on its surface 2. : a legal action that by its nature must have arisen in a… … Useful english dictionary
local circuit theory — A generally accepted model for neuronal conduction, by which depolarization of a small region of a neuronal plasma membrane produces transmembrane currents in the neighbouring regions, tending to depolarize them. As the sodium channels are… … Dictionary of molecular biology
War of Currents — In the War of Currents era (sometimes, War of the Currents or Battle of Currents ) in the late 1880s, George Westinghouse and Thomas Edison became adversaries due to Edison s promotion of direct current (DC) for electric power distribution over… … Wikipedia
Bay Currents — founded by an entrepreneurial journalist in August 2004, is an independent newspaper focusing on oceanfront Brooklyn, N.Y., United States including Sheepshead Bay, Brighton Beach, and Coney Island, United States. It has a readership of about 30 … Wikipedia
Red Sea — The Red Sea is a salt water inlet of the Indian Ocean between Africa and Asia. The connection to the ocean is in the south through the Bab el Mandeb sound and the Gulf of Aden. In the north are the Sinai Peninsula, the Gulf of Aqaba, and the Gulf … Wikipedia
Mediterranean Sea — a sea surrounded by Africa, Europe, and Asia. 2400 mi. (3865 km) long; 1,145,000 sq. mi. (2,965,550 sq. km); greatest known depth 14,436 ft. (4400 m). Also called Mediterranean. * * * Inland sea enclosed by Europe, Africa, and Asia. Its west east … Universalium
Persian Gulf — an arm of the Arabian Sea, between SW Iran and Arabia. 600 mi. (965 km) long. Also called Arabian Gulf. * * * Arm of the Arabian Sea. It is 550 mi (885 km) long and has an average depth of 328 ft (100 m). It is connected with the Gulf of Oman and … Universalium
Old Sow Whirlpool — Old Sow is the name of the largest tidal whirlpool in the Western Hemisphere located off the southwestern shore of Deer Island, New Brunswick, Canada between that island and Moose Island, the principal island of Eastport, Maine.According to… … Wikipedia
Old Sow whirlpool — Old Sow is the largest tidal whirlpool in the Western Hemisphere located off the southwestern shore of Deer Island, New Brunswick, Canada between that island and Moose Island, the principal island of Eastport, Maine. According to popular… … Wikipedia